Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Foods ; 12(4)2023 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-36832780

RESUMO

Mycotoxins are deleterious fungal secondary metabolites that contaminate food and feed, thereby creating concerns regarding food safety. Common fungal genera can easily proliferate in Indian tropical and sub-tropical conditions, and scientific attention is warranted to curb their growth. To address this, two nodal governmental agencies, namely the Agricultural and Processed Food Products Export Development Authority (APEDA) and the Food Safety and Standards Authority of India (FSSAI), have developed and implemented analytical methods and quality control procedures to monitor mycotoxin levels in a range of food matrices and assess risks to human health over the last two decades. However, comprehensive information on such advancements in mycotoxin testing and issues in implementing these regulations has been inadequately covered in the recent literature. The aim of this review is thus to uphold a systematic picture of the role played by the FSSAI and APEDA for mycotoxin control at the domestic level and for the promotion of international trade, along with certain challenges in dealing with mycotoxin monitoring. Additionally, it unfolds various regulatory concerns regarding mycotoxin mitigation in India. Overall, it provides valuable insights for the Indian farming community, food supply chain stakeholders and researchers about India's success story in arresting mycotoxins throughout the food supply chain.

2.
Artigo em Inglês | MEDLINE | ID: mdl-36512547

RESUMO

For the simultaneous identification and quantification of five nitrofurans metabolites in farmed shrimp and fish, 3-amino-2-oxazolidinone (AOZ), 3-amino-5-morpholinomethyl-2-oxazolidinone (AMOZ), 1-aminohydantoine (AHD), semicarbazide (SEM), and 3,5-dinitrosalicylic acid hydrazide (DNSH), an accurate, precise, and specific method was developed. The mixture of water and methanol (60/40; v/v) was found to be the final optimised solvent for injection. The analytical run duration was 7 min, and the mobile phase included 2 mM methanol and ammonium formate. The new reference point for action (RPA) of 0.50 µg kg-1 as per EC/1871/2019 was taken into consideration and evaluated for the performance characteristics as per the CIR (EC)/2021/808 criteria. Specificity, relative retention time (≤0.25%) relative ion ratio (≤40%), linearity (0.25 to 2.0 µg kg-1), trueness (between 82.8 and 118.1%), repeatability (RSDr ≤14%), within lab reproducibility (RSDwr ≤16.9%), CCα (0.32-0.36 µg kg-1), ruggedness and relative matrix effect (≤14.26%) achieved acceptable values.


Assuntos
Nitrofuranos , Espectrometria de Massas em Tandem , Animais , Crustáceos/química , Crustáceos/metabolismo , Peixes/metabolismo , Metanol , Nitrofuranos/química , Nitrofuranos/metabolismo , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem/métodos
3.
Food Chem ; 260: 336-343, 2018 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-29699677

RESUMO

An accurate, reliable and fast multi-residue, multi-class method using ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) was developed and validated for simultaneous determination and quantification of 24 pharmacologically active substances of three different classes (Quinolones including fluoroquinolones, sulphonamides and tetracyclines) in aquaculture shrimps. Sample preparation involves extraction with acetonitrile containing 0.1% formic acid and followed by clean up with n-hexane and 0.1% methanol in water by UPLC-MS/MS within 8 min. The method was validated according to European Commission Decision 2002/657. Acceptable values were obtained for linearity (5-200 µg kg-1), specificity, Limit of Quantification (5-10 µg kg-1), recovery (between 83 and 100%), repeatability (RSD < 9%), within lab reproducibility (RSD < 15%), reproducibility (RSD ≤ 22%), decision limit (105-116 µg kg-1) and detection capability (110-132 µg kg-1). The validated method was applied to aquaculture shrimp samples from India.


Assuntos
Antibacterianos/análise , Cromatografia Líquida de Alta Pressão/métodos , Contaminação de Alimentos/análise , Frutos do Mar/análise , Espectrometria de Massas em Tandem/métodos , Acetonitrilas/química , Animais , Aquicultura , Decápodes/química , Fluoroquinolonas/análise , Índia , Limite de Detecção , Quinolonas/análise , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Sulfonamidas/análise , Tetraciclinas/análise
4.
J AOAC Int ; 100(3): 598-602, 2017 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-28300021

RESUMO

This study enables the selective determination of inorganic arsenic (iAs) with a low detection limit using an economical instrument [atomic absorption spectrometer with hydride generation (HG)] to meet the regulatory requirements as per European Commission (EC) and Codex guidelines. Dry rice samples (0.5 g) were diluted using 0.1 M HNO3-3% H2O2 and heated in a water bath (90 ± 2°C) for 60 min. Through this process, all the iAs is solubilized and oxidized to arsenate [As(V)]. The centrifuged extract was loaded onto a preconditioned and equilibrated strong anion-exchange SPE column (silica-based Strata SAX 500 mg/6 mL), followed by selective and sequential elution of As(V), enabling the selective quantification of iAs using atomic absorption spectrometry with HG. In-house validation showed a mean recovery of 94% and an LOQ of 0.025 mg/kg. The repeatability (HorRatr) and reproducibility (HorRatR) values were <2, meeting the performance criteria mandated by the EC. The combined standard measurement uncertainty by this method was less than the maximum standard measurement uncertainty; thus, the method can be considered for official control purposes. The method was applied for the determination of iAs in husked rice samples and has potential applications in other food commodities.


Assuntos
Arsênio/análise , Análise de Alimentos , Oryza/química , Extração em Fase Sólida , Espectrofotometria Atômica , Peróxido de Hidrogênio , Reprodutibilidade dos Testes , Incerteza
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...